Violation Detail
Standard Cited: 19100217 E01 I Mechanical power presses.
Inspection Nr: 1465424.015
Citation: 01003B
Citation Type: Serious
Abatement Date: 06/23/2020 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/11/2020
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC): R
Gravity: 10
Report ID: 0317500
Contest Date:
Final Order: 07/07/2020
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/07/2020 | $0.00 | 06/23/2020 | Serious | |
| Penalty | Z: Issued | 06/11/2020 | $0.00 | 06/23/2020 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment: a) Shop area, 100 Key Lane, Leechburg, PA 15656: On or about January 17, 2020, the employer did not establish a program of periodic and regular inspections to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment. Barrier guards on the AIDA (model number NC1-2000(2)(E), serial number CO420-0506) gap frame mechanical press were not properly installed and adjusted. Press operators were exposed to an amputation hazard while using the AIDA press to shock washers.
Translate