Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1461639.015
Citation: 01001
Citation Type: Serious
Abatement Date: 06/02/2020 2
Initial Penalty: $13,494.00
Current Penalty: $13,494.00
Issuance Date: 05/06/2020
Nr Instances: 1
Nr Exposed: 20
Related Event Code (REC):
Gravity: 10
Report ID: 0729300
Contest Date:
Final Order: 06/03/2020
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 05/06/2020 | $13,494.00 | 06/02/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and a) On or about 02/03/2020, in the nail production floor, Cell 8, Wafios nail maker, Model N51, Serial 24209271, a twisting wire that exposed the workers to pinch hazards, was not guarded. On 01/29/2020, a worker sustained amputation of his right thumb while in the process of untwisting the wire. b) On or about 02/03/2020, in the nail production area, a rotating wheel on Cell 8, Wafios nail maker, Model N51, Serial No. 24209271, was not full enclosed (guarded).