Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1454913.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 07/30/2020 2
Initial Penalty: $12,145.00
Current Penalty: $8,501.50
Issuance Date: 04/01/2020
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): R
Gravity: 10
Report ID: 0316400
Contest Date:
Final Order: 04/28/2020
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/28/2020 | $8,501.50 | 07/30/2020 | Serious | |
| Penalty | Z: Issued | 04/01/2020 | $12,145.00 | 05/18/2020 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Diamond Electric: On or about January 3, 2020 and times prior, employees performed repairs on automatic coil assemblies with multiple energy sources such as 87psi pneumatic and 208V electric. The employer had not developed, documented or utilized specific energy control procedures for the equipment, during maintenance or testing activities.