Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1452930.015
Citation: 01002
Citation Type: Other
Abatement Date: 03/19/2020 4
Initial Penalty: $7,210.00
Current Penalty: $7,210.00
Issuance Date: 03/09/2020
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity:
Report ID: 0418600
Contest Date:
Final Order: 04/06/2020
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/06/2020 | $7,210.00 | 03/19/2020 | Other | |
| Penalty | Z: Issued | 03/09/2020 | $7,210.00 | 03/19/2020 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a) Putty Line; On or about December 9, 2019 and at times prior thereto the employer exposed employees to potential hazardous energies in that employees were allowed to replace belts on the putty line without shutting it down and locking it out in accordance with the company's Lockout program established procedures.