Violation Detail
Standard Cited: 19100147 D04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1451834.015
Citation: 01001
Citation Type: Serious
Abatement Date: 05/06/2020 2
Initial Penalty: $13,494.00
Current Penalty: $10,000.00
Issuance Date: 03/31/2020
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): R
Gravity: 10
Report ID: 0524500
Contest Date: 04/17/2020
Final Order: 04/16/2021
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 04/16/2021 | $10,000.00 | 05/06/2020 | Serious | |
| Penalty | C: Contested | 04/22/2020 | $13,494.00 | 05/06/2020 | Serious | |
| Penalty | Z: Issued | 03/31/2020 | $13,494.00 | 05/06/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
1910.147(d)(4)(ii): Lockout devices were not affixed in a manner to hold the energy isolating devices in a "safe" or "off" position. On December 17, 2019, employees were exposed to machine hazards associated with moving parts while cleaning rollers on the Pattyn line filler machine. The company failed to implement it energy control procedure for locking out a roller conveyor prior to cleaning off oil from the roller conveyor.