Violation Detail
Standard Cited: 19100219 F01 Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 1442221.015
Citation: 01003
Citation Type: Serious
Abatement Date: 03/25/2020
Initial Penalty: $5,398.00
Current Penalty: $0.00
Issuance Date: 03/13/2020
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): R
Gravity: 10
Report ID: 0111500
Contest Date:
Final Order: 04/10/2020
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/10/2020 | $0.00 | 03/25/2020 | Serious | |
| Penalty | Z: Issued | 03/13/2020 | $5,398.00 | 03/25/2020 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.219(f)(1): Gears were not guarded by one of the methods specified in (1)(i), (1)(ii), or (1)(iii) of this section of this standard: ESTABLISHMENT: The employer did not ensure that gears on the bell paint machine were guarded. On or about September 23, 2019, while an employee was installing a bell support peg, the employee's left pinky finger got caught in the chain and gear assembly, resulting in a partial amputation of the finger.