Violation Detail
Standard Cited: 19260651 I01 Specific Excavation Requirements.
Inspection Nr: 1440686.015
Citation: 01001
Citation Type: Serious
Abatement Date: 12/31/2019 5
Initial Penalty: $3,978.00
Current Penalty: $3,978.00
Issuance Date: 12/16/2019
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): C
Gravity: 10
Report ID: 0111400
Contest Date:
Final Order: 01/13/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 12/16/2019 | $3,978.00 | 12/31/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.651(i)(1): Where the stability of adjoining buildings, walls, or other structures was endangered by excavation operations, support systems such as shoring, bracing or underpinning was not provided to ensure the stability of such structures for the protection of employees. Location: Jobsite 12 Carson Street Dorchester MA. On or about October 28, 2019, an employee was expose to structural collapse hazards while working near an adjacent structure that had not been underpinned or supported during excavation.