Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1439910.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 12/24/2019 2
Initial Penalty: $3,789.00
Current Penalty: $2,652.00
Issuance Date: 11/27/2019
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC): R
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 12/06/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/06/2019 | $2,652.00 | 12/24/2019 | Serious | |
| Penalty | Z: Issued | 11/27/2019 | $3,789.00 | 12/24/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedures to ensure that the procedures and requirements of this standard were followed: JOB SITE: 300A Industrial Drive, Troy, MO 63379, on or about 10/24/2019, the employer fail to conduct an annual inspection of the energy control procedures to ensure that the procedures and requirement were current on but not limited to the following equipment: a) Mark Andy Presses 1, 2, 3 & 4 b) Pic Rewind c) Arpeco Rewind
Translate