Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1439737.015
Citation: 01001
Citation Type: Other
Abatement Date: 02/07/2022 2
Initial Penalty: $10,419.00
Current Penalty: $4,000.00
Issuance Date: 11/20/2019
Nr Instances: 1
Nr Exposed: 32
Related Event Code (REC):
Gravity: 5
Report ID: 0524700
Contest Date: 12/13/2019
Final Order: 01/05/2022
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 01/05/2022 | $4,000.00 | 02/07/2022 | Other | |
| Penalty | C: Contested | 12/16/2019 | $10,419.00 | 12/02/2019 | Serious | |
| Penalty | Z: Issued | 11/20/2019 | $10,419.00 | 12/02/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a. Beverage Packaging North and Central America - Findlay, Ohio: On or about October 14, 2019, a periodic inspection of the energy control procedures was not performed to assure that lockout/tagout procedures and requirements of 29 CFR 1910.147 were being followed. The employer did not ensure that the energy control procedure for Decorator 12 equipment was inspected annually.