Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1438718.015
Citation: 01001C
Citation Type: Serious
Abatement Date: 01/07/2020 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/18/2019
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0625700
Contest Date:
Final Order: 02/25/2020
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/25/2020 | $0.00 | 01/07/2020 | Serious | |
| Penalty | Z: Issued | 12/18/2019 | $0.00 | 01/07/2020 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a) On or about October 9, 2019, in the Fertilizer Department, employees performed maintenance on a multipowered conveyor belt system without training and required skills
Translate