Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1436242.015
Citation: 01001
Citation Type: Serious
Abatement Date: 12/26/2019
Initial Penalty: $8,051.00
Current Penalty: $0.00
Issuance Date: 11/26/2019
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 12/20/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/20/2019 | $0.00 | 12/26/2019 | Serious | |
| Penalty | Z: Issued | 11/26/2019 | $8,051.00 | 12/26/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a) On October 2, 2019, the Vacuum employee was exposed to ingoing nip point hazards while removing sand from between the conveyor powered rollers on Conveyor #233 associated with the 2070 DISA. The Vacuum employee did not implement energy control application steps prior to removing sand between conveyor powered roller on Conveyor #233. As a result, the remaining energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], and verification of isolation [1910.147(d)(6) were not implemented to protect the Vacuum employee from machine servicing hazards.