Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1431197.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 12/23/2019 2
Initial Penalty: $13,127.00
Current Penalty: $13,127.00
Issuance Date: 11/19/2019
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 10
Report ID: 0522500
Contest Date:
Final Order: 12/11/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/11/2019 | $13,127.00 | 12/23/2019 | Serious | |
| Penalty | Z: Issued | 11/19/2019 | $13,127.00 | 12/23/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). a. On or about September 7, 2019, in the belt storage area of building 3, the portable R2214 inclined scrap conveyor belt was not isolated from its electric energy source by unplugging the equipment, at a minimum, while an employee was attempting to locate and/or remove a piece of scrap during servicing activities.