Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1428045.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 01/06/2020 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/03/2019
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 5
Report ID: 0626700
Contest Date:
Final Order: 12/16/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/16/2019 | $0.00 | 01/06/2020 | Serious | |
| Penalty | Z: Issued | 12/03/2019 | $0.00 | 01/06/2020 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a) At the facility, where the Viking 505 Pallet Nailing Machine, serial number 960003 was not shut down while an employee was checking the conveyor sprocket wheels and tension on the chains. This condition exposed an employee to moving machine parts and in-going nip point hazards created by the conveyor sprocket wheels.
Translate