Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1427941.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 02/04/2020 2
Initial Penalty: $9,282.00
Current Penalty: $6,033.00
Issuance Date: 01/13/2020
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 01/28/2020
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/28/2020 | $6,033.00 | 02/04/2020 | Serious | |
| Penalty | Z: Issued | 01/13/2020 | $9,282.00 | 02/04/2020 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Starch drying area; All energy isolating devices associated with but not limited to: peelers, dryers, exhaust fans, rotary sifters, rotary valves and augers were not physically located and operated in such a manner as to isolate the machine or equipment from the energy sources during unjamming, cleaning, servicing, and maintenance of equipment.