Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1414346.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 11/08/2019 2
Initial Penalty: $13,260.00
Current Penalty: $7,956.00
Issuance Date: 10/10/2019
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): R
Gravity: 10
Report ID: 0523300
Contest Date:
Final Order: 11/22/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/22/2019 | $7,956.00 | 11/08/2019 | Serious | |
| Penalty | Z: Issued | 10/10/2019 | $13,260.00 | 11/08/2019 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: On or about July 06, 2019 bread line slicer was not turned off when employees made adjustments to the bread line slicer.
Translate