Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1413438.015
Citation: 01001
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $13,260.00
Current Penalty: $0.00
Issuance Date: 09/17/2019
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0420600
Contest Date: 10/08/2019
Final Order: 04/27/2020
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | R: Review Commission | 04/27/2020 | $0.00 | Serious | ||
| Penalty | C: Contested | 10/10/2019 | $13,260.00 | Serious | ||
| Penalty | Z: Issued | 09/17/2019 | $13,260.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a. At the establishment located on 4700 Middle Ave., Sarasota FL, employees were authorized to do maintenance and/or repairs on equipment, such as but not limited to, Baler # BA01, on or about July 2, 2019.