Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1411175.015
Citation: 01001C
Citation Type: Serious
Abatement Date: 10/29/2019 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/02/2019
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): A
Gravity: 10
Report ID: 0626300
Contest Date:
Final Order: 10/22/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/22/2019 | $0.00 | 10/29/2019 | Serious | |
| Penalty | Z: Issued | 10/02/2019 | $0.00 | 10/29/2019 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) On or about June 19, 2019, in the Sawmill Area, lockout or tagout devices were not affixed to each energy isolating device by authorized employees for the employer's Tipton Iron Works, Inc. Edger.