Violation Detail
Standard Cited: 19100147 C02 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1411175.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 10/29/2019 2
Initial Penalty: $5,304.00
Current Penalty: $3,182.40
Issuance Date: 10/02/2019
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): A
Gravity: 10
Report ID: 0626300
Contest Date:
Final Order: 10/22/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/22/2019 | $3,182.40 | 10/29/2019 | Serious | |
| Penalty | Z: Issued | 10/02/2019 | $5,304.00 | 10/29/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(2)(i): Where an energy isolating device was not capable of being locked out, the employer's energy control program under 29 CFR 1910.147(c)(1) did not utilize a tagout system: (a) On or about June 19, 2019, Tipton Edger Machine, the employer developed a written energy control procedure for the cleaning, maintenance, changing blades, and other servicing activities. The employer did not implement a tagout system when performing cleaning, unjamming and other maintenance activities. This practice exposed employees to moving machine parts and ingoing nip points created by the moving rollers.