Violation Detail
Standard Cited: 19261053 A13 Ladders.
Inspection Nr: 1400209.015
Citation: 01001
Citation Type: Serious
Abatement Date: 10/29/2019 2
Initial Penalty: $6,521.00
Current Penalty: $3,912.60
Issuance Date: 10/11/2019
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0419400
Contest Date:
Final Order: 11/06/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/06/2019 | $3,912.60 | 10/29/2019 | Serious | |
| Penalty | Z: Issued | 10/11/2019 | $6,521.00 | 10/29/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.1053(a)(13): The perpendicular clearance between fixed ladder rungs, cleats, and steps, and any obstruction behind the ladder was less than 7 inches (18 cm). a. Roof Hatch - On or about May 9, 2019 the fixed ladder rungs had less than 7 inches of clearance between the back of the ladder and the roof hatch frame (Fall Hazard).