Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1390380.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 10/15/2019 2
Initial Penalty: $10,210.00
Current Penalty: $10,210.00
Issuance Date: 08/09/2019
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): A
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 09/03/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/03/2019 | $10,210.00 | 10/15/2019 | Serious | |
| Penalty | Z: Issued | 08/09/2019 | $10,210.00 | 08/27/2019 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a.) On or about March 28, 2019, the employer did not ensure that employees were adequately trained in the lockout procedures for the Plastics Line 1301 conveyor. Employees did not lock out and tag out the electrical panel while performing cleaning activities on equipment including, but not limited to the Line 1301 conveyor.
Translate