Violation Detail
Standard Cited: 19100179 J02 Overhead and gantry cranes.
Inspection Nr: 1390034.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 08/30/2019 2
Initial Penalty: $13,260.00
Current Penalty: $7,946.00
Issuance Date: 07/15/2019
Nr Instances: 1
Nr Exposed: 7
Related Event Code (REC):
Gravity: 10
Report ID: 0728900
Contest Date:
Final Order: 08/06/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/06/2019 | $7,946.00 | 08/30/2019 | Serious | |
| Penalty | Z: Issued | 07/15/2019 | $13,260.00 | 08/08/2019 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.179(j)(2): The following items were not be inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections. The employer failed to ensure inspections of hoist/crane units, to include between regular inspections were performed, that would have detected wear on the hoist hook (to connect the work). This was most recently observed on April 2, 2019 at Tenneco, Inc at 111 Izzak Rd Seward, NE 68434. Under the hook operations were not performed adequately in pre use inspection(s) that included lower hook (working end) damages and or wear. Employees on the FCA SCR production line performed Under the hook operations and inspected prior to use, but not inspecting the lower connect hook to prevent the hook failure while operating the hoist movements required in their workplace tasks.