Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1385869.015
Citation: 01001
Citation Type: Serious
Abatement Date: 05/08/2019 2
Initial Penalty: $10,419.00
Current Penalty: $5,209.50
Issuance Date: 04/17/2019
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): R
Gravity: 5
Report ID: 0627100
Contest Date:
Final Order: 05/10/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/10/2019 | $5,209.50 | 05/08/2019 | Serious | |
| Penalty | Z: Issued | 04/17/2019 | $10,419.00 | 05/08/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a) For the employees performing maintenance activities on Gate #5 on the Breast Distribution Conveyor #3377C on or about March 6, 2019 and times prior thereto, the employer did not provide equipment specific lock out tag out procedures that clearly identified the location of the energy isolation sources and verification all energy has been dissipated.
Translate