Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1374002.015
Citation: 01001
Citation Type: Other
Abatement Date: 07/18/2019 2
Initial Penalty: $994.00
Current Penalty: $596.40
Issuance Date: 07/02/2019
Nr Instances: 3
Nr Exposed: 9
Related Event Code (REC):
Gravity:
Report ID: 0419400
Contest Date:
Final Order: 07/09/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/09/2019 | $596.40 | 07/18/2019 | Other | |
| Penalty | Z: Issued | 07/02/2019 | $994.00 | 07/18/2019 | Other |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Planer Mill Department - On or about January 24, 2019, the periodic inspection of lockout / tagout procedures for the strapping machines had not been performed. Employees were exposed to caught-in or between the moving parts of the machinery hazards.