Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1371363.015
Citation: 01002
Citation Type: Serious
Abatement Date: 06/25/2019 2
Initial Penalty: $6,630.00
Current Penalty: $3,315.00
Issuance Date: 06/06/2019
Nr Instances: 1
Nr Exposed: 15
Related Event Code (REC):
Gravity: 5
Report ID: 0523400
Contest Date:
Final Order: 06/27/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/27/2019 | $3,315.00 | 06/25/2019 | Serious | |
| Penalty | Z: Issued | 06/06/2019 | $6,630.00 | 06/25/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees. (a) On or about January 15, 2019, employees working on the Unitrol Solution Welder (Machine BW1, Model #9280D-602 & Serial #S0400508) were exposed to caught-in and crushing hazards while servicing and maintaining equipment. Employees were not provided adequate training to ensure that the purpose and function of the energy control program was understood and how to implement machine specific procedures.