Standard Cited: 19100147 C06 I B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1371249.015
Citation: 01001
Citation Type: Other
Abatement Date: 05/01/2019 2
Initial Penalty: $7,814.00
Current Penalty: $7,814.00
Issuance Date: 03/15/2019
Nr Instances: 1
Nr Exposed: 7
Related Event Code (REC): R
Gravity:
Report ID: 0729300
Contest Date:
Final Order: 04/09/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/09/2019 | $7,814.00 | 05/01/2019 | Other | |
| Penalty | Z: Issued | 03/15/2019 | $7,814.00 | 05/01/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i)(B): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: On or about January 15,019 at the jobsite located 5148 North Hanley, Saint Louis, Missouri, the employer had not conducted periodic inspections to correct any deviations or identify inadequacies of the company's Control of Hazardous Energy Procedures for machines such as, but not limited to the Okuma Cadet CNC (Model: LNC8; Serial Number: C847).