Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1369199.015
Citation: 01002
Citation Type: Serious
Abatement Date: 06/14/2019
Initial Penalty: $10,419.00
Current Penalty: $0.00
Issuance Date: 05/30/2019
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0524500
Contest Date: 06/24/2019
Final Order: 05/26/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/26/2020 | $0.00 | 06/14/2019 | Serious | |
Penalty | C: Contested | 08/02/2019 | $10,419.00 | 06/14/2019 | Serious | |
Penalty | Z: Issued | 05/30/2019 | $10,419.00 | 06/14/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control was not done in sequence as required by 29 CFR 1910.147(d)(1) through (d)(6): On or about December 21, 2018, an employee working in Area T21 was exposed to physical injuries while servicing the M-116 Motor on the Empty Captive Conveyor Line and the employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.