Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1366358.015
Citation: 01003
Citation Type: Serious
Abatement Date: 02/11/2019 2
Initial Penalty: $12,934.00
Current Penalty: $9,053.80
Issuance Date: 12/21/2018
Nr Instances: 96
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 10
Report ID: 0729300
Contest Date:
Final Order: 01/24/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/24/2019 | $9,053.80 | 02/11/2019 | Serious | |
| Penalty | Z: Issued | 12/21/2018 | $12,934.00 | 02/11/2019 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: At 1000 Premier Pkwy, St. Peters, Missouri, specifically inside of the Outbound Department, employee(s) were able to by-pass the fixed, barrier guard attached to the Ranpak Paper Machine, m/n PPLC21, s/n H1743005, by removing three door pins by hand. This violation was noted on 12/19/18.