Violation Detail
Standard Cited: 19100217 B07 III Mechanical power presses.
Inspection Nr: 1364857.015
Citation: 02001
Citation Type: Other
Abatement Date: 04/05/2019 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/05/2019
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC):
Gravity:
Report ID: 0213600
Contest Date:
Final Order: 03/21/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/21/2019 | $0.00 | 04/05/2019 | Other | |
| Penalty | Z: Issued | 03/05/2019 | $0.00 | 04/05/2019 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.217(b)(7)(iii): A means of selecting Off, "Inch," Single Stroke, and Continuous (when the continuous function is furnished) was supplied with the clutch/brake control to select type of operation and the fixing of the selection was not by means capable of supervision by the employer. a) On or about 03/01/19 in the Fabrication Dept.; employer did not supervise the proper use of settings of mechanical power presses, such as but not limited to, Minster # 349, 348, 353, 200, 201, when the keyed selection switch for the stroke setting of theses presses was found with the key in the switch on each press. ABATEMENT CERTIFICATION REQUIRED