Violation Detail
Standard Cited: 19260416 A03 General requirements.
Inspection Nr: 1363332.015
Citation: 01002
Citation Type: Serious
Abatement Date: 02/19/2019 2
Initial Penalty: $3,978.00
Current Penalty: $2,386.80
Issuance Date: 01/30/2019
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0625700
Contest Date:
Final Order: 03/06/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/06/2019 | $2,386.80 | 02/19/2019 | Serious | |
| Penalty | Z: Issued | 01/30/2019 | $3,978.00 | 02/19/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.416(a)(3): Before work is begun the employer shall ascertain by inquiry or direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, is so located that the performance of the work may bring any person, tool, or machine into physical or electrical contact with the electric power circuit. The employer shall post and maintain proper warning signs where such a circuit exists. The employer shall advise employees of the location of such lines, the hazards involved, and the protective measures to be taken. On or about November 28, 2018 at 2277 Hwy 15 Winnsboro, LA 71295, the employer allowed employees to work in the vicinity of less then 10 feet of 19 kv transmission lines.