Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1362396.015
Citation: 01001
Citation Type: Serious
Abatement Date: 06/05/2019 2
Initial Penalty: $4,831.00
Current Penalty: $4,831.00
Issuance Date: 05/07/2019
Nr Instances: 1
Nr Exposed: 200
Related Event Code (REC):
Gravity: 1
Report ID: 0521100
Contest Date:
Final Order: 05/23/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/23/2019 | $4,831.00 | 06/05/2019 | Serious | |
| Penalty | Z: Issued | 05/07/2019 | $4,831.00 | 06/05/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: a) On or about November 28, 2018, the employer's Lockout Tagout Program did not include the method to ensure energy control procedures and the requirements of 29 CFR 1910.147 are being followed at least annually.