Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1356659.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $13,260.00
Current Penalty: $9,282.00
Issuance Date: 04/19/2019
Nr Instances: 1
Nr Exposed: 100
Related Event Code (REC):
Gravity: 10
Report ID: 0729300
Contest Date:
Final Order: 05/01/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/01/2019 | $9,282.00 | Serious | ||
| Penalty | Z: Issued | 04/19/2019 | $13,260.00 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i) Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about 10/26/2018, at the Compounder Area, southwest corner, the employers' Lock Out/Tag Out written program did not contain machine specific procedures for the TPU Hopper #3 Discharge Unit, exposing employees to amputation hazards.