Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1353460.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 04/25/2019 2
Initial Penalty: $9,472.00
Current Penalty: $0.00
Issuance Date: 04/01/2019
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 04/16/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/16/2019 | $0.00 | 04/25/2019 | Serious | |
Penalty | Z: Issued | 04/01/2019 | $9,472.00 | 04/25/2019 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: The employer is failing to inspect the lockout/tagout program annually. An inspection had not been performed for over 17 months. At the time of the initial opening of the inspection, on 10-16-18, the most recent lockout/tagout inspection was dated 4-21-17 ("2016 Lock-out/Tag-out Audit (St. Louis Facilities)". Abatement documentation is required for this violation.