Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1349030.015
Citation: 01002
Citation Type: Serious
Abatement Date: 02/06/2019 2
Initial Penalty: $12,934.00
Current Penalty: $9,701.00
Issuance Date: 12/18/2018
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC):
Gravity: 10
Report ID: 0626700
Contest Date:
Final Order: 01/23/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/23/2019 | $9,701.00 | 02/06/2019 | Serious | |
| Penalty | Z: Issued | 12/18/2018 | $12,934.00 | 02/06/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Eco Services facility: On September 21,2018, the employer did not ensure that all energy isolating devices that were needed to control the energy on track 5 spot 7 were physically located and operated in such a manner as to isolate the equipment from the energy source. This condition exposed employees to chemical burns.
Translate