Violation Detail
Standard Cited: 19100184 E04 Slings.
Inspection Nr: 1345868.015
Citation: 01004
Citation Type: Serious
Abatement Date: 12/14/2018 2
Initial Penalty: $6,467.00
Current Penalty: $4,203.55
Issuance Date: 10/25/2018
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC):
Gravity: 5
Report ID: 0522500
Contest Date:
Final Order: 11/19/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/19/2018 | $4,203.55 | 12/14/2018 | Serious | |
| Penalty | Z: Issued | 10/25/2018 | $6,467.00 | 11/14/2018 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.184(e)(4): Proof testing. The employer shall ensure that before use, each new, repaired, or reconditioned alloy steel chain sling, including all welded components in the sling assembly, shall be proof tested by the sling manufacturer or equivalent entity, in accordance with paragraph 5.2 of the American Society of Testing and Materials Specification A391-65, which is incorporated by reference as specified in Sec. 1910.6 (ANSI G61.1-1968). The employer shall retain a certificate of the proof test and shall make it available for examination. a. On and before October 18, 2018, in the HSP molding department, the employer did not retain a certificate of the proof test for the quadruple alloy steel chain sling and did not make it available for examination. The sling was attached and used with a Gorbel 2 ton jib crane and Budgit 2 ton hoist.