Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1344220.015
Citation: 01002
Citation Type: Serious
Abatement Date: 11/15/2018 2
Initial Penalty: $12,934.00
Current Penalty: $7,113.00
Issuance Date: 10/29/2018
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): A
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 11/13/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/13/2018 | $7,113.00 | 11/15/2018 | Serious | |
| Penalty | Z: Issued | 10/29/2018 | $12,934.00 | 11/15/2018 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a. On or about September 5, 2018, the employer did not ensure employees were adequately trained in the purpose and function of the energy control program. Employees were required to perform activities such as changing the spoil boards on the ONSRUD Model 193G18W8 CNC Router, and are exposed to amputation hazards from pinch points between the boards and table in that the equipment was not properly deenergized.