Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1342279.015
Citation: 01001
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $12,934.00
Current Penalty: $0.00
Issuance Date: 12/12/2018
Nr Instances: 1
Nr Exposed: 9
Related Event Code (REC): R
Gravity: 10
Report ID: 0418300
Contest Date: 01/10/2019
Final Order: 07/15/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | J: ALJ Decision | 07/15/2019 | $0.00 | Serious | ||
| Penalty | C: Contested | 01/11/2019 | $12,934.00 | Serious | ||
| Penalty | Z: Issued | 12/12/2018 | $12,934.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a) On or about 8/13/2018 - 3rd Floor Ice House #1, an employee did not utilize the established Lockout/Tag out procedure while unjamming an ice blockage in the ice machine chute.