Violation Detail
Standard Cited: 19100147 F03 II The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1341698.015
Citation: 01003
Citation Type: Serious
Abatement Date: 02/21/2019
Initial Penalty: $9,282.00
Current Penalty: $0.00
Issuance Date: 02/07/2019
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): R
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 03/05/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/05/2019 | $0.00 | 02/21/2019 | Serious | |
| Penalty | Z: Issued | 02/07/2019 | $9,282.00 | 02/21/2019 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(f)(3)(ii): Group lockout or tagout devices were not used in accordance with procedures required by 29 CFR 1910.147(c)(4): a) Industrial Machining Services, Inc. (IMS) at the address of 216 Southgate Drive in Minster, Ohio; On or about August 22, 2018, the employer did not ensure group lock out devices were affixed to pneumatic disconnects prior performing service and maintenance activities in Danone North America's plant. Two employees who were tasked with replacing the cluster valve body of valve 282AV1342 were exposed to hazards associated with high temperature liquids in that a group lock out device was not applied. An employee suffered second and third degree burns to their arms, legs and mid-section when adjacent valve 282AV1230 was pulsed upstream and emptied into the drain where the employee was working.