Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1338481.015
Citation: 01002
Citation Type: Serious
Abatement Date: 03/01/2019 2
Initial Penalty: $5,497.00
Current Penalty: $3,847.90
Issuance Date: 12/14/2018
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0418300
Contest Date:
Final Order: 01/09/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | P: Petition to Mod Abatement | $3,847.90 | 03/01/2019 | Serious | ||
| Penalty | I: Informal Settlement | 01/09/2019 | $3,847.90 | 01/31/2019 | Serious | |
| Penalty | Z: Issued | 12/14/2018 | $5,497.00 | 12/27/2018 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: (a) On or about 08/02/2018 - Production area, periodic inspections were not conducted for all equipment such as, but not limited to, E-Z Lok Deck Mill (Dhalstrom, 400-16, S/N 1136).