Violation Detail
Standard Cited: 19100147 F01 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1333206.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 02/08/2019 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/18/2018
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 5
Report ID: 0111400
Contest Date:
Final Order: 01/16/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 12/18/2018 | $0.00 | 02/08/2019 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(f)(1)(ii): In situations in which lockout or tagout devices were temporarily removed from the energy isolating device and the machine or equipment was energized to test or position the machine, equipment, or component thereof, the following sequence of actions was not followed in that removal of employees from the machine or equipment area was not in accordance with paragraph (e)(2) of this section: 80 East Belcher Road, Foxboro, Massachusetts: An employee assisting with the troubleshooting and adjustment of a Terex TBC430 Drum Chipper was not removed from the hazardous area where the belt guard had been removed prior to the chipper being re-started.