Violation Detail
Standard Cited: 19100147 D05 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1332451.015
Citation: 01001D
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/10/2018
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): R
Gravity: 10
Report ID: 0419400
Contest Date:
Final Order: 03/13/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/13/2019 | $0.00 | Serious | ||
| Penalty | Z: Issued | 12/10/2018 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001D Hazard:
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: (a) Production area - During the period January 11, 2018 through July 11, 2018 the employer did not require employees to bleed air and water pressure on blow molding machines prior to opening weep holes during color change process.
Translate