Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1327583.015
Citation: 01002
Citation Type: Serious
Abatement Date: 09/04/2018 2
Initial Penalty: $9,054.00
Current Penalty: $6,000.00
Issuance Date: 07/31/2018
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): R
Gravity: 10
Report ID: 0134000
Contest Date:
Final Order: 08/13/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/13/2018 | $6,000.00 | 09/04/2018 | Serious | |
| Penalty | Z: Issued | 07/31/2018 | $9,054.00 | 09/04/2018 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Location - 30 Porter Road, Littleton, MA: On or about 7/5/2018, the point of operation of the Atom Model S6110DF 110 Ton Hydraulic Press S/N 19C150002 was not effectively safeguarded.
Translate