Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1324188.015
Citation: 01001
Citation Type: Serious
Abatement Date: 09/07/2018 2
Initial Penalty: $9,054.00
Current Penalty: $4,527.00
Issuance Date: 08/13/2018
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): R
Gravity: 10
Report ID: 0728500
Contest Date:
Final Order: 08/31/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/31/2018 | $4,527.00 | 09/07/2018 | Serious | |
| Penalty | Z: Issued | 08/13/2018 | $9,054.00 | 09/07/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): At the location of 301 Carmeco Road, Lebanon, Missouri: Employees bending metal on the Pacific K400-14 press were exposed to the point of operation while bending and shaping metal.
Translate