Violation Detail
Standard Cited: 19100147 C04 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1323204.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 09/20/2019 2
Initial Penalty: $12,934.00
Current Penalty: $8,934.00
Issuance Date: 08/23/2018
Nr Instances: 1
Nr Exposed: 11
Related Event Code (REC): R
Gravity: 10
Report ID: 0112600
Contest Date:
Final Order: 09/20/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/20/2018 | $8,934.00 | 09/20/2019 | Serious | |
| Penalty | Z: Issued | 08/23/2018 | $12,934.00 | 10/11/2018 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures: 30 liter polisher machines; U.S. Tsubaki, 106 Lonczak Dr., Chicopee, Massachusetts; On and before June 18, 2018 the employer's energy control procedures for the 30 liter polishing machines did not provide for a method to verify the pressure was released from the barrel after opening the relief nut and prior to opening the barrel at the end of the polishing cycle.