Violation Detail
Standard Cited: 19260502 D21 Fall protection systems criteria and practices.
Inspection Nr: 1322252.015
Citation: 01003
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $5,174.00
Current Penalty: $3,363.00
Issuance Date: 10/10/2018
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0215300
Contest Date:
Final Order: 11/01/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/01/2018 | $3,363.00 | Serious | ||
| Penalty | Z: Issued | 10/10/2018 | $5,174.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service: a. On or about June 19, 2018, at the service area building, at Yacht Haven Grande. Employee was installing metal roofing when he fell 22 feet to the ground below. The lanyard (rope) he was attached to broke 10 feet 5 inches from the anchorage point causing employee to fall onto the ground below. The rope had multiple kinks throughout, showed an appearance of being worn and was not removed from service. NOTE: Certification of abatement is not required for this citation item as abatement was documented by the compliance safety and health officer during the inspection.