Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1321222.015
Citation: 01001
Citation Type: Serious
Abatement Date: 1
Initial Penalty: $8,811.00
Current Penalty: $4,400.00
Issuance Date: 09/12/2018
Nr Instances: 1
Nr Exposed: 7
Related Event Code (REC): R
Gravity: 5
Report ID: 0418300
Contest Date: 10/09/2018
Final Order: 05/13/2019
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | J: ALJ Decision | 05/13/2019 | $4,400.00 | Serious | ||
| Penalty | C: Contested | 10/11/2018 | $8,811.00 | Serious | ||
| Penalty | Z: Issued | 09/12/2018 | $8,811.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or about 05/29/2018 - Z Calendar Wind Up, a procedure was not developed, documented, and utilized to address the specific activity of removing stuck fabric from the Z Calendar Wind Up.
Translate