Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1309050.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 10/01/2018 2
Initial Penalty: $9,147.00
Current Penalty: $5,030.85
Issuance Date: 08/31/2018
Nr Instances: 6
Nr Exposed: 12
Related Event Code (REC):
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 09/20/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/20/2018 | $5,030.85 | 10/01/2018 | Serious | |
| Penalty | Z: Issued | 08/31/2018 | $9,147.00 | 10/01/2018 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: On or about April 5, 2018 the employer did not provide specific procedural steps to secure tension arms on the wire carrier to prevent struck-by hazards to employees when pressure from the arm and/or wire is released.