Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1302219.015
Citation: 01002
Citation Type: Serious
Abatement Date: 08/14/2018 2
Initial Penalty: $5,174.00
Current Penalty: $3,104.40
Issuance Date: 07/19/2018
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 5
Report ID: 0418200
Contest Date:
Final Order: 08/01/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/01/2018 | $3,104.40 | 08/14/2018 | Serious | |
| Penalty | Z: Issued | 07/19/2018 | $5,174.00 | 08/14/2018 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. a) Copper Wire Process Area: On or about March 5, 2018, and at times prior, the employer exposed employees to amputation hazards while cutting copper cables utilizing a hydraulic alligator shear (McIntyre Model 407 Serial number 36711996) that was not properly guarded.