Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1299752.015
Citation: 01001
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $10,477.00
Current Penalty: $6,286.20
Issuance Date: 05/01/2018
Nr Instances: 3
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0625700
Contest Date:
Final Order: 05/10/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/10/2018 | $6,286.20 | Serious | ||
Penalty | Z: Issued | 05/01/2018 | $10,477.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: On or about 3/6/18 in the Machine Shop; the employer allowed employees to operate the Amada Hydraulic Press Brake, the 367 VC Punch Press (model Apel10 III), the Ellis Mitre Band Saw (model 1600) and the Adria Hydraulic Press without the use of machine-specific procedures to lock out and tag out the equipment.