Violation Detail
Standard Cited: 19100147 F01 V The control of hazardous energy (lockout/tagout).
Inspection Nr: 1296549.015
Citation: 01001
Citation Type: Serious
Abatement Date: 06/25/2018 2
Initial Penalty: $9,054.00
Current Penalty: $5,500.00
Issuance Date: 05/24/2018
Nr Instances: 1
Nr Exposed: 14
Related Event Code (REC): R
Gravity: 10
Report ID: 0524500
Contest Date: 06/21/2018
Final Order: 12/24/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | R: Review Commission | 12/24/2018 | $5,500.00 | 06/25/2018 | Serious | |
| Penalty | C: Contested | 06/27/2018 | $9,054.00 | 06/25/2018 | Serious | |
| Penalty | Z: Issued | 05/24/2018 | $9,054.00 | 06/25/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(f)(1)(v): All systems were not de-energized and energy control measures reapplied in accordance with paragraph (d) of this section to continue servicing and/or maintenance. On or about February 20, 2018, employees working in the service department were exposed to amputation hazards and the employer had not ensured the vehicle was turned off before performing automotive drive belt installation, removal, replacement, or repair.
Translate