Violation Detail
Standard Cited: 19100147 F03 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1294875.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 03/06/2018 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/23/2018
Nr Instances: 1
Nr Exposed: 36
Related Event Code (REC): R
Gravity: 5
Report ID: 0524700
Contest Date:
Final Order: 03/16/2018
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/16/2018 | $0.00 | 03/06/2018 | Serious | |
| Penalty | Z: Issued | 02/23/2018 | $0.00 | 03/06/2018 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment: A) Toledo Molding & Die, Inc., located at 515 East Gypsy Lane Road, Bowling Green, OH 43402: On or about February 7, 2018, the employer did not ensure that each employee affixed a personal lockout or tagout device to the main electrical disconnect of the Cincinnati Milacron hydraulic deflash press BDP03, located next to the Press # 42, before two employees were setting up the 9015 deflash die inside the Cincinnati Milacron hydraulic deflash press BDP03.